ISCATECH   Bedoukian   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Chemtica
Biochemtech
AlphaScents
U-Chemo
BIOHOME
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractSand aspiration: a case report and review of the radiological features and management    Next AbstractThe moderating effect of religiosity on the genetic variance of problem alcohol use »

Anaesthesia


Title:Evaluation of the novel, single-use, flexible aScope for tracheal intubation in the simulated difficult airway and first clinical experiences
Author(s):Piepho, T. Werner, C. Noppens, R. R.
Address:Department of Anaesthesiology, University Medical Centre of Johannes Gutenberg-University, Mainz, Germany.
Year:2010 Aug
Journal Title:Anaesthesia
Page Number:820-5
Language:eng
Volume:65
Issue:8
ISSN/ISBN:1365-2044 (Electronic). 0003-2409 (Linking)
Abstract:Flexible fibreoptic intubation is widely accepted as an important modality for the management of patients with difficult airways. We compared the aScope, a novel, single-use, flexible video-endoscope designed to aid tracheal intubation, with a standard flexible intubating fibrescope, by examining the performance of 21 anaesthetists during an easy and difficult intubation simulation in a manikin. Intubation success, time for intubation, and rating of the devices (using a scale from 1, excellent to 6, fail) were documented. Intubation times were similar for both flexible 'scopes in the scenarios (p = 0.59). Successful intubation rates were higher for the standard intubating fibrescope (17/21, 81%) than the aScope (14/21, 67%; p = 0.02) in the difficult intubation scenario. The median (IQR[range]) ratings for the standard fibrescope vs the aScope were respectively: overall, 2 (1.75-2 [1-2.5]) vs 3 (2-3.25 [1-5]) (p < 0.0001); picture quality 2 (1.5-2 [1-3]) vs 3 (2-4 [1-5]) (p < 0.0001). The aScope was also successfully used to facilitate tracheal intubation in five patients with anticipated or unanticipated difficult airways. Picture quality was sufficient to identify the anatomical landmarks. Although the performance of the aScope is acceptable, it does not meet the current quality of standard flexible intubation fibrescopes.

 
Back to top
 
Citation: El-Sayed AM 2021. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2021 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 16-01-2021